A healthy adult ear notices a silence of about 5 milliseconds buried in noise: 50 normal-hearing listeners in the original Gaps-In-Noise (GIN) study averaged 4.8 ms in the left ear and 4.9 ms in the right ear (Musiek et al., Ear and Hearing 2005). That small number is a working benchmark for temporal resolution, meaning how finely the auditory system can follow fast changes in sound over time. It moves quickly with hearing status: 50 adults with mild-to-moderate sensorineural hearing loss had a median GIN threshold of 10.00 ms against 4.00 ms in 50 normal-hearing adults (Abd El-Ghaffar et al., Journal of Otology 2026), and infants aged 6 to 7.5 months needed 30 to 40 ms on a harder cross-frequency version of the task where adults needed 10 to 20 ms (Smith, Trainor and Shore, JSLHR 2006). Gap tests are a core part of the auditory processing batteries described in our pediatric auditory processing disorder prevalence roundup, but this page looks only at the threshold numbers themselves. We aggregated data from Ear and Hearing, the Journal of the Acoustical Society of America (JASA), the Journal of Speech, Language, and Hearing Research (JSLHR), the Journal of the American Academy of Audiology (JAAA), PeerJ, Trends in Hearing, Clinical Neurophysiology, and a dozen other peer-reviewed sources.
TL;DR
- 50 normal-hearing adults averaged a GIN threshold of 4.8 ms (left) and 4.9 ms (right) (Musiek et al., Ear and Hearing 2005).
- Age explained 17.1% of gap threshold variance in 30 adults aged 21 to 59 with normal audiograms (Gómez-Álvarez et al., Trends in Hearing 2023).
- A tablet-based gap test gave a grand mean of 2.36 ms in 150 US undergraduates (Lelo de Larrea-Mancera et al., JASA 2020).
- Infants scored 11 ms, 5-year-olds 5.6 ms and adults 5.2 ms on a same-frequency gap task (Trehub et al., JASA 1995).
- 72 children aged 7 to 18 showed no developmental effect on GIN thresholds (Shinn, Chermak and Musiek, JAAA 2009).
- Older adults with hearing loss averaged 8.60 ms on the GIN vs 4.53 ms in young adults (Hoover, Pasquesi and Souza, JAAA 2015).
- Adults with sensorineural hearing loss: median 10.00 ms vs 4.00 ms in normal-hearing peers (Abd El-Ghaffar et al., Journal of Otology 2026).
- Gap identification correlated with word recognition at r = 0.88 in 11 cochlear implant users (Sagi et al., JSLHR 2008).
- Adults with auditory neuropathy averaged 8.6 ms, ranging from 5 to 15 ms (Michalewski et al., Clinical Neurophysiology 2009).
- Blast-exposed Veterans averaged 7.1 ms (right ear) vs 4.6 ms in controls (Papesh and Koerner, Seminars in Hearing 2024).
- Children with APD needed 98.1 ms vs 51.75 ms on a cross-frequency gap task (Jain et al., International Archives of Otorhinolaryngology 2025).
- Vocal musicians detected gaps of 1.81 ms vs 2.47 ms in non-musicians (Kumar, Sanju and Nikhil, International Archives of Otorhinolaryngology 2015).
1. The Normal Baseline: How Short a Silence Healthy Adults Detect
The clinical answer clusters tightly around 5 ms. The original GIN norms (4.8 ms left, 4.9 ms right) and a 2025 Thai sample (5.04 ms) sit within about a quarter of a millisecond of each other, even though they were collected two decades and an ocean apart. The GIN reports an “approximate threshold” (the shortest gap a listener detects consistently in the test list) plus an overall percent correct score, and in the Thai data the two were tightly linked (Spearman rho = -0.840 for both ears) (Jeanbunjongkij et al., PeerJ 2025).
The bigger spread comes from method, not geography. Other laboratory and tablet procedures land well below the GIN’s 5 ms: 2.36 ms in a 150-student tablet study and 3.6 ms in a laboratory sample of 30 adults. The practical reading is that a “gap threshold” only means something next to the name of the test that produced it (see section 3 for the same effect in older listeners).
| Metric | Value | Source |
|---|---|---|
| GIN approximate threshold, 50 normal-hearing adults, left ear vs right ear | 4.8 ms vs 4.9 ms | Musiek et al., Ear and Hearing 2005 |
| GIN approximate threshold, 52 young Thai adults (mean age 20.16), both ears | 5.04 ms (SD 0.68) | Jeanbunjongkij et al., PeerJ 2025 |
| GIN overall percent correct, same Thai sample, both ears | 71.35% (SD 6.72) | Jeanbunjongkij et al., PeerJ 2025 |
| Published GIN norms, right ear: South Korea vs Poland | 4.95 ms vs 5.4 ms | Choi et al. 2013 and Majak et al. 2015, as compiled in PeerJ 2025 |
| Published GIN norm, Brazil, both ears | 4.19 ms (78.89% correct) | Samelli and Schochat 2008, as compiled in PeerJ 2025 |
| Tablet gap test (PART), 150 US undergraduates, grand mean | 2.36 ms (SD 3.16) | Lelo de Larrea-Mancera et al., JASA 2020 |
| Same tablet gap test, correlation between two test sessions | r = 0.55 (p < 0.01) | Lelo de Larrea-Mancera et al., JASA 2020 |
| Laboratory gap threshold, 30 adults aged 21 to 59 with normal audiograms | 3.6 ms (SD 1.9) | Gómez-Álvarez et al., Trends in Hearing 2023 |
Context note: the tablet test took about 5 minutes per assessment, short enough to fit inside a routine visit. Its session-to-session correlation of r = 0.55 is moderate, a reminder that a single short run is noisy at the individual level.
2. Development: From Infancy to the Teenage Years
Children are not simply small adults on this task, but the gap closes earlier than many people expect. With markers in the same frequency band, 5-year-olds averaged 5.6 ms against 5.2 ms for 21-year-olds, while infants averaged 11 ms (Trehub, Schneider and Henderson, JASA 1995). By school age, GIN scores look adult-like: 72 children aged 7 to 18 showed no developmental effect at all (Shinn, Chermak and Musiek, JAAA 2009).
The harder version tells a different story. In a “between-channel” task, the sound before the gap and the sound after it sit at different frequencies (here 1 and 4 kHz tones), so the brain must compare timing across separate frequency channels. There, infants aged 6 to 7.5 months needed 30 to 40 ms where adults needed 10 to 20 ms, a sign that comparing timing across channels matures later than following a single channel (Smith, Trainor and Shore, JSLHR 2006).
| Metric | Value | Source |
|---|---|---|
| Same-frequency gap threshold (d’ = 0.5): infants vs 5-year-olds vs 21-year-olds | 11 ms vs 5.6 ms vs 5.2 ms | Trehub, Schneider and Henderson, JASA 1995 |
| Between-channel gap threshold (1 and 4 kHz tone markers): infants aged 6 to 7.5 months vs adults | 30 to 40 ms vs 10 to 20 ms | Smith, Trainor and Shore, JSLHR 2006 |
| Children aged 7 to 18 tested on the GIN, effect of age on threshold | 72 children, no developmental effect | Shinn, Chermak and Musiek, JAAA 2009 |
| GIN mean threshold, 75 children aged 8 to 10 | 4.7 ms (SD 0.7), 73.6% correct | Amaral and Colella-Santos, Brazilian Journal of Otorhinolaryngology 2010 |
| GIN mean threshold at age 8 vs age 9 vs age 10 | 4.8 ms vs 4.6 ms vs 4.7 ms (p = 0.6132) | Amaral and Colella-Santos, Brazilian Journal of Otorhinolaryngology 2010 |
| Proposed cutoff for abnormal GIN performance, ages 8 to 10 | 6.1 ms and 60% correct | Amaral and Colella-Santos, Brazilian Journal of Otorhinolaryngology 2010 |
| Random Gap Detection Test (RGDT) vs GIN (right ear), 28 children aged 8 to 10 | 9.25 ms (SD 3.67) vs 4.32 ms (SD 0.61) | Amaral, Martins and Colella-Santos, Brazilian Journal of Otorhinolaryngology 2013 |
| Adaptive forced-choice vs non-adaptive GIN procedure, 18 children and 20 adults | Both groups had significantly lower thresholds with the adaptive procedure | Veeranna et al., JAAA 2024 |
Outlier note: the age at which children reach adult GIN levels is contested. The 2010 Brazilian paper lists earlier studies placing it at 7, 9, 10 or 12 years, and its own data point to development by about age 7. Most recent available data for school-age GIN norms: Amaral and Colella-Santos, 2010 and 2013; the 2024 JAAA study did not publish new millisecond norms in its abstract.
3. Aging: What Changes in Older Listeners, and What Does Not
The aging data split in two, and the split is mostly about hearing loss riding along with age. Older adults with hearing loss averaged 8.60 ms on the GIN, nearly double the 4.53 ms of young normal-hearing adults (Hoover, Pasquesi and Souza, JAAA 2015). Yet a study that used band-limited noise in older listeners with near-normal hearing found almost no age gap (8.8 ms vs 9.0 ms), and age plus hearing level explained only 3.9% of the variance in gap thresholds (Shen, JSLHR 2014).
Even within the normal-audiogram range, age leaves a measurable fingerprint: in 30 adults aged 21 to 59, age explained 17.1% of gap threshold variance (R² = .171, p = .023), and that link disappeared once a cognitive inhibition score was controlled (Gómez-Álvarez et al., Trends in Hearing 2023). The same study found that its main proxy for cochlear synaptopathy (damage to the nerve connections inside the inner ear) was not significantly related to gap thresholds (R² = .097, p = .094), a nuance worth reading next to our cochlear synaptopathy and hidden hearing loss roundup.
| Metric | Value | Source |
|---|---|---|
| GIN threshold, 19 young normal-hearing adults (mean age 24.6) vs 11 older adults with hearing loss (mean age 64.9) | 4.53 ms vs 8.60 ms (p < 0.001) | Hoover, Pasquesi and Souza, JAAA 2015 |
| Traditional adaptive gap threshold, same two groups | 2.99 ms vs 4.23 ms (p < 0.001) | Hoover, Pasquesi and Souza, JAAA 2015 |
| Correlation between GIN and traditional gap thresholds | r = 0.70 (p = 0.02) | Hoover, Pasquesi and Souza, JAAA 2015 |
| Correlation between GIN threshold and QuickSIN speech-in-noise score | r = 0.645 (p < .01) | Hoover, Pasquesi and Souza, JAAA 2015 |
| Band-limited gap threshold (geometric mean), 9 young (19 to 21) vs 24 older listeners (55 to 88) | 8.8 ms vs 9.0 ms | Shen, JSLHR 2014 |
| TMTF cutoff frequency, young vs older listeners | 51.0 Hz vs 69.7 Hz | Shen, JSLHR 2014 |
| Gap threshold variance explained by age plus pure-tone average | 3.9% (p = .55) | Shen, JSLHR 2014 |
| Gap threshold variance explained by age, 30 adults aged 21 to 59 with normal audiograms | R² = .171 (p = .023) | Gómez-Álvarez et al., Trends in Hearing 2023 |
Context note: a temporal modulation transfer function (TMTF) measures how well a listener detects a sound that rhythmically gets louder and softer, across many fluctuation speeds; its “cutoff frequency” is the speed beyond which detection starts to fall off. In the Shen data, only TMTF sensitivity (14.6 dB young vs 13.0 dB older) changed with age, and the gap and TMTF measures barely correlated in older listeners (r = .01). The newest aging data, a 2025 JSLHR study of 18 younger and 18 older listeners, also reported age-related declines in behavioral gap thresholds alongside slower cortical responses to gaps (Mussoi et al., JSLHR 2025).
4. Hearing Loss and Cochlear Implants
The newest clinical dataset, from 2026, shows adults with mild-to-moderate sensorineural hearing loss needing a median gap of 10.00 ms, two and a half times the 4.00 ms of normal-hearing adults (Abd El-Ghaffar et al., Journal of Otology 2026). The same team recorded brain responses to the gaps (an electrophysiological GIN, which does not require the patient to press a button) and found it tracked the behavioral score almost perfectly in the hearing-loss group (Spearman rs = 0.959). That matters for listeners who cannot give reliable behavioral responses. How hearing loss itself progresses with age is covered in our presbycusis progression roundup.
Cochlear implants are the striking counterexample. An implant bypasses the inner ear entirely, yet many postlingually deafened users (people who lost hearing after learning to speak) detect electrical gaps about as well as typical listeners detect acoustic ones. One reading of that pattern is that much of the work of gap detection happens after the inner ear (human thresholds summarized in Kirby and Middlebrooks, JARO 2012).
| Metric | Value | Source |
|---|---|---|
| Behavioral GIN threshold (median), 50 normal-hearing adults vs 50 adults with mild-to-moderate sensorineural hearing loss | 4.00 ms vs 10.00 ms (p < 0.001) | Abd El-Ghaffar et al., Journal of Otology 2026 |
| Electrophysiological GIN threshold (median), same two groups | 2.00 ms vs 8.00 ms (p < 0.001) | Abd El-Ghaffar et al., Journal of Otology 2026 |
| Electrophysiological GIN at a 4 ms cutoff: sensitivity vs specificity | 84% vs 90% | Abd El-Ghaffar et al., Journal of Otology 2026 |
| Electrophysiological GIN, area under the ROC curve | 0.903 (95% CI 0.857 to 0.949) | Abd El-Ghaffar et al., Journal of Otology 2026 |
| Gap thresholds from low to high stimulus level: cochlear implant users vs normal-hearing listeners | 20 to 50 ms down to 2 to 5 ms vs about 25 ms down to 2 ms | Sagi et al., JSLHR 2008 (summary of earlier studies) |
| Gap thresholds of implant users with little or no open-set speech recognition | Can be greater than 50 ms | Sagi et al., JSLHR 2008 (summary of earlier studies) |
| Gap identification score vs CNC word recognition, 11 implant users | r = 0.88 (p < 0.001) | Sagi et al., JSLHR 2008 |
| Electrical gap thresholds in earlier studies: postlingually deafened users (at up to 1,000 pulses per second) vs prelingually deafened implant users | 1 to 5 ms vs 1 to 50 ms | Kirby and Middlebrooks, JARO 2012 (summary of earlier studies) |
Context note: the electrical figures come from older psychophysics studies quoted in later papers. Most recent available data for implant gap thresholds as a group: Kirby and Middlebrooks, 2012; Sagi et al., 2008. “Open-set” speech recognition means understanding words without a list of choices to pick from.
5. Neurological Conditions: Brain Lesions, Auditory Neuropathy and Blast Exposure
The GIN was validated on patients with neurological lesions, and that original dataset still frames how clinics read it. Eighteen people with confirmed lesions of the central auditory nervous system averaged 7.8 ms (left) and 8.5 ms (right), against 4.8 and 4.9 ms in normal listeners (Musiek et al., Ear and Hearing 2005). A 2020 meta-analysis pooled 9 studies with 221 neurological patients (stroke, epilepsy and blast exposure) and 262 controls (Filippini et al., JAAA 2020).
Auditory neuropathy, where the inner ear works but the signal along the hearing nerve is disrupted, is the condition most tied to temporal deficits. In a small study, people with auditory neuropathy averaged 8.6 ms, above the normal limits of 1.6 to 5.2 ms, and poorer gap detection went with poorer speech understanding in quiet (Michalewski et al., Clinical Neurophysiology 2009). Prevalence and diagnosis numbers for the condition are in our auditory neuropathy spectrum disorder roundup.
| Metric | Value | Source |
|---|---|---|
| GIN threshold, 18 people with confirmed central auditory nervous system lesions, left ear vs right ear | 7.8 ms vs 8.5 ms | Musiek et al., Ear and Hearing 2005 |
| Specificity of a 5 ms GIN cutoff | 84.0% | Musiek et al. 2005, as reported in Jeanbunjongkij et al., PeerJ 2025 |
| Psychoacoustic gap threshold, 8 adults with auditory neuropathy (mean) | 8.6 ms (range 5 to 15 ms) | Michalewski et al., Clinical Neurophysiology 2009 |
| Normal limits (plus or minus 2 SD), 12 normal-hearing controls | 1.6 to 5.2 ms | Michalewski et al., Clinical Neurophysiology 2009 |
| Gap threshold vs speech recognition in quiet, auditory neuropathy group | r = -0.73 (p < 0.05) | Michalewski et al., Clinical Neurophysiology 2009 |
| GIN threshold, right ear: 16 blast-exposed Veterans vs 9 age-matched controls | 7.1 ms (SD 2.4) vs 4.6 ms (SD 1.6) | Papesh and Koerner, Seminars in Hearing 2024 |
| GIN threshold, left ear: same two groups | 7.9 ms (SD 2.1) vs 5.6 ms (SD 1.7), group effect p = 0.006 | Papesh and Koerner, Seminars in Hearing 2024 |
| GIN meta-analysis: included studies, neurological patients vs controls | 9 studies; 221 vs 262 participants | Filippini et al., JAAA 2020 |
Context note: the blast study used 8 ms and above as its threshold for abnormally poor temporal resolution, and poorer left-ear GIN thresholds were associated with slower P3 brain responses (Kendall tau-b = 0.538, p = 0.001). With 25 participants, all male, the authors call for larger samples. Most recent available data for auditory neuropathy gap thresholds: Michalewski et al., 2009.
6. Special Groups: APD, Tinnitus and Musical Training
Auditory processing disorder (APD), a difficulty making sense of sound despite normal hearing sensitivity, shows up most clearly on the hardest version of the task. Children with APD needed 98.1 ms on a cross-frequency gap test, close to double the 51.75 ms of typically developing children (p = 0.000), while the simpler broadband-noise test separated the groups less clearly (5.25 ms vs 2.19 ms, p = 0.068) (Jain, Tanniru and Kalarikkal, International Archives of Otorhinolaryngology 2025). The cross-frequency test flagged 9 of the 12 children with APD.
Tinnitus is the cautionary tale: the idea that a ringing ear “fills in” silent gaps sits behind the startle-based gap tests used in animal research, but human data do not support it as a diagnostic test. A 2024 study found gap thresholds lower overall in controls than in young adults with tinnitus and normal hearing, yet concluded the method cannot identify tinnitus in an individual (Negri et al., Journal of Integrative Neuroscience 2024), and a 2015 study found no group effect at all (Boyen, Başkent and van Dijk, Ear and Hearing 2015). Musical training, by contrast, comes with consistently sharper gap detection in small samples.
| Metric | Value | Source |
|---|---|---|
| Broadband-noise gap threshold (both ears averaged), 12 children with APD vs 12 typically developing children aged 10 to 12 | 5.25 ms vs 2.19 ms (p = 0.068) | Jain, Tanniru and Kalarikkal, International Archives of Otorhinolaryngology 2025 |
| Cross-frequency gap threshold (2 kHz then 1 kHz markers), children with APD vs typically developing children | 98.1 ms vs 51.75 ms (p = 0.000) | Jain, Tanniru and Kalarikkal, International Archives of Otorhinolaryngology 2025 |
| Share of children with APD scoring above the typical mean plus 1 SD: cross-frequency vs broadband vs same-frequency test | 75% vs about 50% vs about 33.33% | Jain, Tanniru and Kalarikkal, International Archives of Otorhinolaryngology 2025 |
| Silent gap detection inflection-point threshold, 20 young adults with tinnitus vs 33 controls | Lower overall for controls than for tinnitus participants (F(1,24) = 12.3, p < 0.01) | Negri et al., Journal of Integrative Neuroscience 2024 |
| Startle-reflex gap test (GPIAS), tinnitus vs controls | No differences between groups | Negri et al., Journal of Integrative Neuroscience 2024 |
| Gap detection, 22 adults with tinnitus vs 20 adults matched for age and hearing loss | No main group effect (p > 0.25) | Boyen, Başkent and van Dijk, Ear and Hearing 2015 |
| Gap threshold, 15 vocal musicians vs 15 non-musicians aged 20 to 30 | 1.81 ms (SD 0.39) vs 2.47 ms (SD 0.48) | Kumar, Sanju and Nikhil, International Archives of Otorhinolaryngology 2015 |
| Binaural gap threshold vs age when musical training began, 27 musicians | r = 0.542 (p < 0.01) | Wang et al., Frontiers in Neuroscience 2025 |
Context note: in the 2025 Frontiers study the gap was not a silence but a brief moment where the two ears received unrelated noise, detected only by comparing ears. Early-trained musicians (n = 15) beat both late-trained musicians and non-musicians (eta squared = 0.340), while years of training did not predict thresholds (r = -0.005). Starting age, not total practice, carried the effect.
Summary: Gap Detection Threshold by the Numbers
| Metric | Value | Source |
|---|---|---|
| GIN threshold, 50 normal-hearing adults, left ear vs right ear | 4.8 ms vs 4.9 ms | Musiek et al., Ear and Hearing 2005 |
| GIN threshold, 52 young Thai adults, both ears | 5.04 ms | Jeanbunjongkij et al., PeerJ 2025 |
| Tablet gap test (PART), 150 US undergraduates | 2.36 ms | Lelo de Larrea-Mancera et al., JASA 2020 |
| Same-frequency gap threshold: infants vs 5-year-olds vs adults | 11 ms vs 5.6 ms vs 5.2 ms | Trehub et al., JASA 1995 |
| Between-channel gap threshold: infants 6 to 7.5 months vs adults | 30 to 40 ms vs 10 to 20 ms | Smith, Trainor and Shore, JSLHR 2006 |
| Children aged 7 to 18 on the GIN | No developmental effect (n = 72) | Shinn, Chermak and Musiek, JAAA 2009 |
| Proposed abnormal GIN cutoff, children aged 8 to 10 | 6.1 ms | Amaral and Colella-Santos, Brazilian Journal of Otorhinolaryngology 2010 |
| RGDT vs GIN (right ear), children aged 8 to 10 | 9.25 ms vs 4.32 ms | Amaral, Martins and Colella-Santos, Brazilian Journal of Otorhinolaryngology 2013 |
| GIN threshold, young normal-hearing adults vs older adults with hearing loss | 4.53 ms vs 8.60 ms | Hoover, Pasquesi and Souza, JAAA 2015 |
| Gap threshold variance explained by age plus hearing level (near-normal older listeners) | 3.9% | Shen, JSLHR 2014 |
| GIN threshold (median), normal hearing vs mild-to-moderate sensorineural hearing loss | 4.00 ms vs 10.00 ms | Abd El-Ghaffar et al., Journal of Otology 2026 |
| Electrical gap thresholds: postlingually vs prelingually deafened implant users | 1 to 5 ms vs 1 to 50 ms | Kirby and Middlebrooks, JARO 2012 |
| Gap threshold, adults with auditory neuropathy (mean) | 8.6 ms | Michalewski et al., Clinical Neurophysiology 2009 |
| GIN threshold (right ear), blast-exposed Veterans vs controls | 7.1 ms vs 4.6 ms | Papesh and Koerner, Seminars in Hearing 2024 |
| Cross-frequency gap threshold, children with APD vs typically developing | 98.1 ms vs 51.75 ms | Jain, Tanniru and Kalarikkal, International Archives of Otorhinolaryngology 2025 |
| Gap threshold, vocal musicians vs non-musicians | 1.81 ms vs 2.47 ms | Kumar, Sanju and Nikhil, International Archives of Otorhinolaryngology 2015 |
Methodology and Sources
- Musiek et al., GIN (Gaps-In-Noise) test performance in subjects with confirmed central auditory nervous system involvement, Ear and Hearing 2005
- Jeanbunjongkij et al., Auditory processing ability in Thai native speakers with the Gaps-In-Noise (GIN) test, PeerJ 2025 (also the source for the compiled Korean, Polish and Brazilian norms and the 5 ms specificity figure)
- Lelo de Larrea-Mancera et al., Portable Automated Rapid Testing (PART) for auditory assessment, JASA 2020
- Gómez-Álvarez et al., cochlear synaptopathy and reduced inhibition in people with normal audiograms, Trends in Hearing 2023
- Trehub, Schneider and Henderson, Gap detection in infants, children, and adults, JASA 1995
- Smith, Trainor and Shore, between-channel gap detection in infants and adults, JSLHR 2006
- Shinn, Chermak and Musiek, GIN performance in the pediatric population, JAAA 2009
- Amaral and Colella-Santos, GIN performance of school-aged children, Brazilian Journal of Otorhinolaryngology 2010
- Amaral, Martins and Colella-Santos, temporal resolution assessment procedures for school-aged children, Brazilian Journal of Otorhinolaryngology 2013
- Veeranna, Christensen and Chapman, adaptive vs nonadaptive gap detection in children and adults, JAAA 2024
- Hoover, Pasquesi and Souza, Comparison of clinical and traditional gap detection tests, JAAA 2015
- Shen, gap detection and TMTF in young and older adults, JSLHR 2014
- Mussoi et al., spectrotemporal processing and degraded speech in younger and older adults, JSLHR 2025
- Abd El-Ghaffar et al., electrophysiological GIN test in sensorineural hearing loss, Journal of Otology 2026
- Sagi et al., temporal gap identification and speech perception in cochlear implant users, JSLHR 2008
- Kirby and Middlebrooks, auditory cortex codes for gaps in cochlear implant pulse trains, JARO 2012
- Filippini, Wong, Schochat and Musiek, GIN test: a meta-analysis on its neurodiagnostic value, JAAA 2020
- Michalewski, Starr, Zeng and Dimitrijevic, N100 cortical potentials in auditory neuropathy, Clinical Neurophysiology 2009
- Papesh and Koerner, clinical Gaps-in-Noise measures in blast-exposed Veterans, Seminars in Hearing 2024
- Jain, Tanniru and Kalarikkal, children with and without APD on adaptive gap detection, International Archives of Otorhinolaryngology 2025
- Negri et al., optimization of the operant silent gap-in-noise detection paradigm in humans, Journal of Integrative Neuroscience 2024
- Boyen, Başkent and van Dijk, The gap detection test: can it be used to diagnose tinnitus?, Ear and Hearing 2015
- Kumar, Sanju and Nikhil, temporal resolution in vocal musicians, International Archives of Otorhinolaryngology 2015
- Wang et al., early musical training and binaural gap detection, Frontiers in Neuroscience 2025
- Data watch: gap thresholds are not interchangeable across tests. GIN values run higher than adaptive laboratory thresholds in the same people (4.53 ms vs 2.99 ms in Hoover et al. 2015), and the RGDT runs higher still in children, so every figure here should be read with its test name. Most studies are small (8 to 150 participants) and many are older than three years; the most recent available data for infant development (1995, 2006), implant users (2008, 2012) and auditory neuropathy (2009) predate 2023. Several sources have internal inconsistencies we did not use as headline stats: the 2025 PeerJ paper reports some p-values differently in its text and tables and labels the 2005 GIN norms as English data, the 2010 Brazilian paper gives conflicting p-values for its sex comparison, and the 2024 tinnitus paper reports per-stimulus threshold pairs (for example at 2 and 8 kHz) without saying which value belongs to which group, and its Table 4 lists only control values, so we report only its overall group result and do not publish per-group milliseconds. In the Abd El-Ghaffar 2026 study the hearing-loss group was older on average than the controls (32.63 vs 26.73 years), so age and hearing status are not fully separated. Larger tablet-battery datasets from India (2023) and from Spanish-speaking listeners exist, but we could not verify their gap values, so they are not included.
Last updated: November 8, 2026. We update this roundup quarterly, and the next refresh is expected when the 2027 volumes of Ear and Hearing and the Journal of the American Academy of Audiology publish new Gaps-In-Noise normative and clinical data.